How To Reduce Simulation Time In Comsol

How To Reduce Simulation Time In ComsolYou know what, COMSOL forum modulator deleted my post and banned my account very quickly. By the way by default the logfile is deleted upon closing COMSOL, except if you say otherwise in the (Options. Comsol Acoustics Introduction, 2012 Tutorial Created in Comsol 4. The software supports single-physics and fully coupled multiphysics modeling capabilities, simulation data management, and easy-to-use tools for building . You can reduce computational time and memory by using a Periodic, Perfectly Matched Layer, or Symmetry boundary condition. In this course, attendees will be led through the use of COMSOL Multiphysics with a focus on use of the Study Node and associated settings. Our #Multiphysics #simulation models, data analysis tools, Reduced Order Models, . Try changing it to the D:/ drive in settings. Introduction to Designing Microwave Circuits Using EM Simulation. Where do you save your mph files to reduce the impact on the memory ? A bit of context: I am running CFD simulations but they are quite heavy since I am also running parameter sweeps as well that impact on my laptop memory ( ~500Gb) Currently I am saving on one drive to reduce the impact but as I run more simulations the problem returns hitting. Method to Reduce Calculation Time in Multiphysics Modelling of. Therefore, it is always a good idea to reduce the tolerances and repeat the simulation. The frequency response is obtained by considering the Delta-Function model whose equations are implemented in COMSOL. there are varous possibilites you can try to control such models. I was just addressing the problem you described of the simulation stopping before it finishes. this model was imported from COMSOL library of models. My first guess would be lack of convergence during time step. In time dependent study simulation in COMSOL, we need to define range in study setting as below: range (time1, TIME, time2) This means that the simulation will be study between time1 and time2, the time duration in each time step is adaptive but it can not bigger than TIME and in each TIME the results will be saved. In the figure below, the temperature distribution and heat flux are shown for a certain time when simulating the moving circular spot with a prescribed temperature of 450 K. How to simulate correctly the time. Once the flow field is computed, we also want to plot and compute the following: Residence time distribution function; Cumulative distribution function; Mean residence time; Variance. The plotting tools in COMSOL Multiphysics include the following histogram plot types: Histogram (1D and 2D plots ), which shows how a quantity is distributed over the geometry (i. The plotting tools in COMSOL Multiphysics include the following histogram plot types: Histogram (1D and 2D plots ), which shows how a quantity is distributed over the geometry (i. This report is involving simulation of Droplet Breakup in a T-junction model. In 1D histograms, the x -axis represents the values of the quantity (as a number of bins or a range of values), and the y -axis represents the count. The coil is charged by an electric circuit (cir). Some times saying, out of memory and . Fast turnaround time enables simulation to influence decisions early in the product design process and eliminate costly re-designs. Without any more information on the model/simulation, it is hard to speak to how many iterations you should run. Model Methods allow recording and executing strings of commands, similar to a macro which you can then edit or create custom commands to add functionality to your Modeling. COMSOL Moderator. In 1D, this boils down to integration by parts, which gives the weak form. Controlling the Time Dependent solver timesteps. The simulations are run from 80 MHz to 200 MHz with a frequency step of 1 MHz. In both cases, I use MUMPS with exactly the same options. In front of the hot spot, a darker shade with 260 K is visible. Co-simulations with Comsol have been currents with a considerably shorter simulation time. When a waveguide is operating on its dominant mode, 2D modeling techniques help to reduce the simulation time drastically. This greatly reduces the simulation time. This can lead to different results if there is something significant happening immediately after the start time. The aim of this presentation is to propose a complete model solving the heat and fluid flow equations in all the states (solid – liquid - gas) of the metal during keyhole laser welding with COMSOL Multiphysics ®. Using Symmetry to Reduce Model Size. Only specifying a lower maximum time step I can achieve a realistic solution. One of the ways you can simplify and reduce the size of a finite element model is by using any symmetries present in your model. 0 Replies Last Post 21 juin 2015, 14:31 UTC−4. I am trying to solve the solution with function: U = mphgetu (model) After that I have to update the S-function states, in the Update (block) of the S-Function with command: model. The plotting tools in COMSOL Multiphysics include the following histogram plot types: Histogram (1D and 2D plots ), which shows how a quantity is distributed over the geometry (i. How to reduce the computation time of a time dependent 2d. 1) in your times settings intervals. Micah G Bullock. Without any more information on the model/simulation, it is hard to speak to how many iterations you should run. This report is involving simulation of Droplet Breakup in a T-junction model. There are several possibilities that could be causing your simulation to run slowly: 1. Entergy has adopted advanced modeling and simulation tools that allow engineers to "walk through" the entire outage in a virtual model, thus avoiding unanticipated surprises. You could run your results first by using the coarser mesh then refine it manually or. Critical solver settings in the Study Node. Whether you are building the geometry natively in COMSOL Multiphysics ® or importing a design from an external file, there are modeling strategies as well as features in the software that you can use to take advantage of such symmetries. 2: You can enter several sequential ranges e. Learn how cyclic symmetry can help reduce memory usage when modeling computationally taxing geometries by using a predefined boundary condition in COMSOL. Third, apply the product rule of derivatives and the divergence theorem to reduce (weaken) the highest order spatial derivative of the dependent variable in the weighted integral. When you have smaller mesh size, you are forced to reduce the time step. However, with the Structural Mechanics Module you can easily. How could I improve speed of my comsol file?. 1) Using symmetry boundary conditions to reduce the size of the problem. Perhaps you can take advantage of any symmetry in your model. COMSOL wants to democratize simulation in the design process– TV-report so large that it is approaching the limit of market penetration. Increase engineering productivity through standardization on a single complete capability for structural simulation. Modeling and Simulation Tools Reduce Plant Outage Duration. Periodic boundary conditions are used to reduce simulation time. Well, recently I ran into a COMSOL simulation problem and went to COMSOL's own forum to post and ask for user's input and help. Hello Fereshteh Samiee If you still need help with COMSOL and have an on-subscription license, please visit our Support Center for help. I was just addressing the problem you. Change some values of the parameters. So, you should use the built-in Fcn block whenever possible. My first guess would be lack of convergence during time step. It really really saves a lot! 2) Depending on what you are looking for, do a mesh refinement study. I would like to simulate the temperature profile during laser drilling with an ultra short pulse laser. A diplexer is a device that combines or splits signals into two different frequency bands, widely used in mobile communication systems. In this case, we can reduce the problem to a two-dimensional computational model, as shown in the image below. When modeling computationally taxing geometries, you can save time by using cyclic symmetry to cut down on. Tutorial on COMSOL Multiphysics Platform. If we check the study nodes of the model, we find two stationary study steps. Re-solving the model with a tighter relative tolerance, as well as re-solving with a finer mesh, is how you get the solver to reduce the timestep and verify . Time required for simulation. resolventtip #comsol #multiphysics #simulation #resolvent. Also, wisely re-meshing the structure will reduce the simulation further. Note that the software is still free to. The model is reduced due to the symmetry of the heat exchanger. Significant reduction of the need for costly physical testing. I will try changing the drive to D:/ but I dont think that would help in improving computation time. I am simulating piezoacoustic transducer in comsol. In my case, the 2D simulation has about twice the DoF than the 3D simulation, and yet the computation duration and memory consumption for the 3D is much more demanding. If you can play around with the mesh sizes and perhaps not allocate. When modeling computationally taxing geometries, you can save time by using cyclic symmetry to cut down on memory usage. Unfortunately, this approach can also mean repeating commands multiple times that can be time consuming and may introduce mistakes. I am simulating piezoacoustic transducer in comsol. Comsol Acoustics Introduction, 2012 Tutorial Created in Comsol 4. Note that the software is still free to choose a timestep smaller than this value, but will not make it larger. Using Cyclic Symmetry to Reduce Computation Time. We appreciate people who want to support this channel with a donation:Paypal: https://www. (decreasing the step time!!!! ) Thanks. White, Comsol Acoustics Introduction, 2012 Finite Element Analysis (FEA / FEM) Numerical Solution of P. I want to excite a pulse from the transducer that passes as pressure. I mean decrease the accuracy just in case to know how changes affect the simulation. COMSOL uses the finite element method to simulate and with higher/lower evacuation time. Effect of changing critical settings. 0 Replies Last Post Jun 21, 2015, 2:31 p. It is important to note that the default time-stepping scheme for this kind of. This drastically reduces the simulation speed. The first time dependent step with a small time resolution to capture the laser pulse and the second time dependent step with larger time. (decreasing the step time!!!! ) Thanks Fereshteh. To plot the solution along a line for several time values, define the line as above and choose “Cut Line 2D” in the 1D Plot Group. I will try changing the drive to D:/ but I dont think that would help in improving computation time. Try changing it to the D:/ drive in settings. As you can see in the model attached, (COMSOL 4. This greatly reduces the simulation time. This greatly reduces the simulation time. I am using time domain 2 Dimensional analysis. Hello Fereshteh Samiee If you still need help with COMSOL and have an on-subscription license, please visit our Support Center for help. Try changing it to the D:/ drive in settings. You can reduce computational time and memory by using a Periodic, Perfectly Matched Layer, or Symmetry boundary condition. The first step is to define a scalar that we can use in a relational or logical expression. The first time dependent step with a small time resolution to capture the laser pulse and the second time dependent step with larger time stepping to capture the heat transfer. Simulation files directory : COMSOL. 1: Use two study steps in your study. The problem is that the pulse duration . 1,10) and the default solver settings (Fully Coupled, Constant (Newton), Direct, and Minimal Jacobian update) and a sinusoidal coil excitation of 10 A, we find that the solution spanning 5 periods (end time 10 s) is achieved in about 100 time steps. The second step was to use three eigenmodes as incident waves inside the duct: (m,n) = (4, 0), (17, 1), and (24, 1). We appreciate people who want to support this channel with a donation:Paypal: https://www. I will try changing the drive to D. To specify the initial time step size, go to the Time-Dependent Solver settings, Time Stepping section, enable the Initial step: option and enter a fixed initial step size, as shown in the screenshot below. The simulation is taking a whole lot of time. Using Cyclic Symmetry to Reduce Computation Time. (decreasing the step time!!!! ) Thanks. This scalar can either be a quantity defined at some point of interest. Methods to reduce computational memory and CPU time. I am simulating piezoacoustic transducer in comsol. I Know Comsol uses an error estimation to respect the absolute . This report is involving simulation of Droplet Breakup in a T-junction model. I am using time domain 2 Dimensional analysis. In the first study step, only laminar flow ( spf) is selected for solving, while in the second study step, heat transfer ( ht) is selected together with the multiphysics coupling nonisothermal flow ( nitf1 ). The simulation is taking a whole lot of time. this model was imported from COMSOL library of models. Without any more information on the model/simulation, it is hard to speak to how many iterations you should run. Using Cyclic Symmetry to Reduce Computation Time. Reduce the Fan Noise of a Turbofan Aeroengine with Simulation. the following items will be covered: Structure of the Study Node. Since the initial and ambient temperatures in the simulation are 293 K, this is not expected. FORUM Time steps decrease abruptly after stopping a time dependent simulation. I want to excite a pulse from the transducer that passes as pressure waves through the water domain and hit a target in the water domain and reflect back to the transducer. In order to track dynamically the keyhole shape, a level set function is employed and the momentum equations are solved to predict. Simulation time for 2D and 3D vastly different (with. Try changing it to the D:/ drive in settings. Due to the nonlinearity and difficulty in predicting the behaviour of bodies coming into and go out of contact, the need of software able to simulate a . Regardless of the dimension in 3D or 2D, the simulation time should, in my opinion, solely depend on the number of DoF. In this paper we show how time-dependent optimal control problems can be solved using the equation-based modeling and simulation environment Comsol . Abacus vs COMSOL Multiphysics Simulation. Normally the time to solve is reported in the lower info window, but I beleive its only there and dissapears once you close COMSOL, in fact I cannot find it in the log file either (Solve - View Log) where I expected to find it too. Hi, while using 2D simulation of your problem, please reduce the out of plane width to match your geometry. So I would just reduce the simulation timestep by factor of 10 and run the . COMSOL with linear model enabled knows NOTHING about saturation so Most of my simulation times were about 1-3 seconds per simulation. In this video, We will learn how to use 2D axisymmetric for modeling of our 3D symmetrical geometry to save the computation time. Reduce the time step size or total computational time. Time dependent study simulation. I was just addressing the problem you described of the simulation stopping before it finishes. The aim of this presentation is to propose a complete model solving the heat and fluid flow equations in all the states (solid – liquid - gas) of the metal during keyhole laser welding with COMSOL Multiphysics ®. Also making the mesh finer (decreasing Element size) would need more simulation time and more processing power (depending on your model it may not even run on . White, Comsol Acoustics Introduction, 2012 Finite Element Analysis (FEA / FEM) Numerical Solution of P. The key required parameter is the SAW velocity, that defined the delay-line operating frequency. The simulation process was done by using COMSOL version 5. I am trying to simulate the variable capacitor of microscale but it's taking almost 2 hours to simulate. This should result in smaller time steps and improve . How to reduce the computation time of a time. (decreasing the step time!!!! ) Thanks Fereshteh. You need to play based on some trial and error 1. Image of water flow around obstructions in a reactor. How can I speed up simulation of my Simulink model?. The simulation process was done by using COMSOL version 5. Hi, while using 2D simulation of your problem, please reduce the out of plane width to match your geometry. In time dependent study simulation in COMSOL, we need to define range in study setting as below: range (time1, TIME, time2) This means that the simulation will be study between time1 and time2, the time duration in each time step is adaptive but it can not bigger than TIME and in each TIME the results will be saved. flir ros; shenandoah acres campground map; loud house fanfiction ronnie anne pregnant; om642 vacuum pump removal; led flush mount light costco; doe meaning in punjabi. In this video, two dimensional heat transfer problem is solved using COMSOL Multiphysics software. With the Times list for the Time-dependent solver set to range(0,0. That is because of the CFL number. 1: Use two study steps in your study. I mean decrease the accuracy just in case to know how changes affect the simulation. 2) to debug your model, check the energy fluxes in & out of your model (integrate over the boundaries) you might well be loosing energy where you do no expect it 3) last you have the pressure defined at several places but I lack some coherence, I would use ather ambant pressure for the initial condition, then perhaps also at outlet -- Good luck. In COMSOL Multiphysics, a stop condition can be added to the following solvers: Time-dependent solver. If you wish to evaluate the tabled-results in separate tables, then open the "Derived values" menu in the Results node by left-clicking the plus in front of it. You have a MATLAB Function Block - When a MATLAB Fcn block is present, the MATLAB interpreter is called at each time step. How to overcome this error "Last time step not Converged" in Comsol. Comsol Acoustics Introduction, 2012 Tutorial Created in Comsol 4. COMSOL software. To evaluate an integral of an . Right-click the probe you want to see, choose "Evaluate => New table" and you're done ! Best regards, Ruud Borger, Comsol. The first step was to investigate circumferential wave numbers (m = 4, 17, and 24) and generate various eigenmodes that correspond to different radial mode numbers. Thus, multiplying (1) by a test function and integrating over the domain, we obtain (5). All to simulate the electromagnetic force. Now you can reduce the time that this process takes and ensure uniformity of implementation by using the Model Methods available in COMSOL Multiphysics ® version 5. Stationary solver with a parametric or auxiliary sweep. To specify the initial time step size, go to the Time-Dependent Solver settings, Time. In time dependent study simulation in COMSOL, we need to define range in study setting as below: range (time1, TIME, time2) This means that the simulation will be study between time1 and time2, the time duration in each time step is adaptive but it can not bigger than TIME and in each TIME the results will be saved. This can be more complex for rotationally than axially symmetric geometries. So I would just reduce the simulation timestep by factor of 10. × Warning Your internet explorer is in compatibility mode and may not be displaying the website correctly. To specify the initial time step size, go to the Time-Dependent Solver settings, Time Stepping section, enable the Initial step: option and enter a fixed initial step size, as shown in the screenshot below. In this video, We will learn how to use 2D axisymmetric for modeling of our 3D symmetrical geometry to save the computation time. Regardless of the dimension in 3D or 2D, the simulation time should, in my opinion, solely depend on the number of DoF. You can cancel or stop the solver process if the model's solving time or .